Hydro Turbine Generator Water Turbine for Hyro Power Plant

Hydro Turbine Generator   Water Turbine for Hyro Power Plant

Hydro Turbine Generator / H2o Turbine for Hyro Energy Plant

Solution  Description

1.Francis 
The Francis turbine are largely suitable for hydro electricity station with medium or substantial head. The francis turbine we supply are compact in framework,reasonable in design and style,convenient in procedure and routine maintenance and excellent in efficency. They are each vertical and horizontal shaft arrangement and can be vastly selected by the hydraulic electrical power station.
 
two.Pelton
Pelton turbine also known as a free-jet turbine or Pelton wheel, a variety of impulse turbine, named after L. A. Pelton who invented it in 1880. H2o passes by way of nozzles and strikes spoon-shaped buckets or cups arranged on the periphery of a runner, which causes the runner to rotate, creating mechanical vitality. The runner is fastened on a shaft, and the rotational movement of the turbine is transmitted by the shaft to a generator.
The impulse type turbines created by Fuchun are ranging from eighty to 1,000m in h2o head,200kW to 20MW in capability and .fifty five to two.3 in runner diameter. Theirs shaft arrangements are possibly vertical or horizontal and they may have single nozzle, twin or multi-nozzles.

three.Kaplan
Kaplan turbine also known as axial movement Turbine is produced in 1913 by the Austrian professor Kaplan.Its invention allowed efficient electrical power manufacturing in low-head applications that was not possible with Francis turbines.The attribute of  Kaplan turbine is the h2o movement passes through the runner axially.
Kaplan turbines are widely utilized during the entire world for electrical energy creation. They protect the least expensive head hydro web sites and are specially suited for large movement situations.

four.Tubular
The tubular turbines are the ideal assortment for exploitation of tidal energy and hydraulic electricity with very reduced heads and incredibly massive stream charges. They have large discharge,higher certain and high performance, and need considerably less excavation.They have been categorized into Bulb, Pit, Siphon and S” sorts in the light of their structural kinds.

Company Information
   Our firm is an skilled manufacture and engineering Company in little scale hydro electricity gear ( 100Kw to 50Mw). We engage in the function of manufacture and EPC contractor and could provide h2o to wire equipments and services. As turbine manufacture more than fifty several years encounter.
   Our manufacturing unit occupies 560,000 square meters of land, which involves 18 workshops, over 320 sets of weighty and precision generating and testing machinery scientific investigation advancement heart in the southern China, and a variety of testing facilities. We have a common technical staff of 380 and 135 senior technical pros. 
  We supply customers with the comprehensive package deal, from the design and manufacture of the turbine, generator and management gear by means of to installation, commissioning and ongoing restore and upkeep.
1.H2o Turbine Generator Device Design & Provide
2.Hydropower equipment supply 
three.Feasibility examine of hydropower project
4.Manufacture
five.Installation & Supervision
6.Commissioning and Coaching service
7. Hydro power plant rehabilitant
8. Hydro electrical power plant spares provide
nine.Solutions

Reference Record of Some Export Assignments
No. Region and Electrical power Station Exported to CZPT Parameters Sort Qty Day of deal
1 HPP2
 Guatemala
Rated head:305m
Rated stream:.385m³/s
Frequency:60Hz
Outgoing line voltage:480V
CJA475-W-eighty/2×6.5
SFW1000-8/1180
one 2013.06
2  Pakistan  Sort:HL855a
Runner diameter:1750mm
27Mw spare runners  one 2013.06
3 Uk Rated head:73.8m
Rated flow:.1325m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-fifty five/1×7 one 2013.03
4 turkey Rated head:203m
Rated movement:.312m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-80/1×8.5
SFW500-8/990
1 2013.05
5 Sri Lanka Rated head:88m
Rated circulation:1.41m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLA550-WJ-62
SFW1000-six/1180
1 2013.05
6 Congo Rated head:210m
Rated circulation:.423m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-eighty/1×9.five
SFW700-8/1180
1 2013.05
seven  
Ecuador
Rated head:925m
Rated circulation:.26m³/s
Frequency:60Hz
Outgoing line voltage:4.16KV
CJC601-W-100/1×5
SFW1980-six/1430
2 2012.twelve
8 Philippines  Rated head:4m
Rated movement:10m³/s
Frequency:60Hz
Outgoing line voltage:440V
ZD-LH-a hundred and sixty
SF320-36/2150
one 2012.twelve
nine  Guatemala Rated head:128m
Rated flow:.six+.3m³/s
Frequency:60Hz
Outgoing line voltage:440V
CJA475-W-eighty/2×9
SFW614-twelve/1180
CJA475-W-80/2×6.5
SFW302-12/990
two 2012.11
10 United kingdom Rated head:48.51m
Rated stream:.351m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-55B/1×8.five 1 2012.11
eleven  UK Rated head:forty seven.48m
Rated movement:.38m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL110-WJ-42 one 2012.eleven
twelve British isles Rated head:twenty five.44m
Rated movement:.332m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-50 one 2012.eleven
thirteen United kingdom Rated head:35.19m
Rated stream:.3m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-fifty 1 2012.11
14 United kingdom Rated head:37.82m
Rated movement:.291m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD54-WJ-50 one 2012.11
15  HPP1
 Guatemala 
Rated head:60m
Rated circulation:1.24m³/s
Frequency:60Hz
Outgoing line voltage:440V
HLA575c-WJ-56
SFW600-eight/990
two 2012.8
16 British isles Rated head:58.1m
Rated flow:.169m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-forty/1×9
SFW100-eight/590
1 2012.04
17 Ecuador Rated head:38m
Rated circulation:1.64m³/s
Frequency:60Hz
Outgoing line voltage:440V
HL220-WJ-50
SFW470-8/990
1 2012.04
18 Italy  Rated head:43m
Rated movement:.59m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL110-WJ-42
HLD54-WJ-forty
2 2012.03
19  Pakistan  Kind:HL855a
Runner diameter:1750mm
27Mw spare runners  three 2011.eleven
20 ITALY Rated head:134m
Rated circulation:.25m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA475-W-80/2×6.5
SFW250-ten/850
2 2011.06
21 Italy Rated head:228m
Rated stream:.4m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA475-W-eighty five/1×9.five
SFW715-8/1180
three 2011.05
22  UK Rated head:sixty one.8m
Rated circulation:.221m³/s
Frequency:50Hz
Outgoing line voltage:400V
XJA-W-42/1×10
SFW100-eight/590
1 2011.03
23 HPP1
Albania
Rated head:379.7m
Rated flow:.685m³/s
Frequency:50Hz
Outgoing line voltage:ten.5KV
CJA475-W-one hundred and five/2×7.five
SFW2150-8/1730
1 2571.twelve
24  HPP2
Albania
Rated head:461.6m
Rated flow:.786m³/s
Frequency:50Hz
Outgoing line voltage:10.5KV
CJA475-W-one hundred fifteen/2×8
SFW3000-eight/1730
one 2571.twelve
25  Italy  Rated head:29m
Rated flow:3.2m³/s
Frequency:50Hz
Outgoing line voltage:400V
HLD41-WJ-forty two
HLD74-WJ-sixty
two 2571.twelve
26 Afghanistan  Rated head:36m
Rated movement:1.67m³/s
Frequency:50Hz
Outgoing line voltage:400V
HL295-LJZ-50
SF500–6/850
five 2571.12
27  
Pakistan
Rated head:206m
Rated circulation:.89m³/s
Frequency:50Hz
Outgoing line voltage:six.6kV
CJA475-W-one hundred/2×10
SFW1500-10/1430
2 2571.08
28  HPP1
Vietnam
Rated head:385m
Rated flow:eleven.24m³/s
Frequency:50Hz
Outgoing line voltage:thirteen.8kV
HL69-LJ-205
SF37500-10/3600
two 2571.02
29  
Mozambique
Rated head:206.8m
Rated circulation:.358m³/s
Frequency:50Hz
Outgoing line voltage:400V
CJA237-W-eighty/1×9
SFW570-eight/990
one 2571.04
30 Pakistan  Rated head:forty seven.5m
Rated stream:two.62m³/s
Frequency:50Hz
Outgoing line voltage:six.6kV
HLA696-WJ-68
SFW1000-8/1180
3 2571.03
31  Italy  Rated head:35m
Rated circulation:4.25m³/s
Frequency:50Hz
HLA696-WJ-82
SFW800-twelve/1430
HLJF2504-WJ-56
SFW400-8/990
three 2571.01
32 Italy  Rated head:265m
Rated stream:.734m³/s
Frequency:50Hz
Outgoing line voltage:six.3kV
CJA475-W-a hundred and ten/2×8.five
SFW1600-10/1730
2 2009.07
33 Georgia Rated head:289m
Rated movement:1.775m³/s
Nozzle No.:two
Bucket No.: twenty
Runner Outer Diameter: 1600mm
RUNNER DIAMETER: 1300mm
4000KW Pelton runner change  three 2009.06
34 Vietnam Rated head:86.2m
Rated stream:22.5m³/s
Frequency:50Hz
Outgoing line voltage:ten.5kV
HLA883-LJ-one hundred fifty five
SF17000-twelve/3250
two 2009.01

Hydro Turbine Generator   Water Turbine for Hyro Power Plant

Leave a Reply

Your email address will not be published. Required fields are marked *